Doppler velocimeter is a velocity and flow detection instrument applied to rivers, open channels and pipelines. Using ultrasonic detection technology, it has the advantages of high measurement accuracy, good stability, little influence by environmental factors, no rotating parts, low maintenance frequency and high working reliability, and is the first choice for portable velocity and flow measurement.
product details

Doppler velocimeter is a velocity and flow detection instrument applied to rivers, open channels and pipelines. Using ultrasonic detection technology, it has the advantages of high measurement accuracy, good stability, little influence by environmental factors, no rotating parts, low maintenance frequency and high working reliability, and is the first choice for portable velocity and flow measurement.

1. Product Introduction

Acoustic Doppler velocimeter is a flow velocity and flow rate detection instrument applied to rivers, open channels and pipelines. It adopts ultrasonic detection technology, with high measurement accuracy, good stability, less affected by environmental factors, no rotating parts, low maintenance frequency, and high working reliability. It is the preferred product for portable flow velocity and flow rate measurement.

Principle: In the field of acoustics, when there is a relative motion between the sound source and the receiving body (i.e. the probe and the reflector), the frequency of the echo will change, this frequency change is called frequency shift, i.e. the Doppler effect. The sound wave frequency increases when it moves towards the observer and decreases when it moves away from the observer. The Doppler flow meter calculates the flow rate by calculating the frequency change.

2. Application fields

Sponge city, river chief system management, inland river monitoring, natural rivers, open channels, pipelines, aquaculture and other scenarios.

Three, main features

  1. Measuring the flow, velocity, and water level of pipes, channels, and natural rivers.

  2. Single flow sensor, easy to install, suitable for municipal sewers,不滿 pipe pipelines, various channels, irregular rivers, natural streams, drainage outlets, etc. for flow measurement, and can be concealed installed, can achieve long-term stable operation.

  3. Instantaneous flow values and cumulative flow values can be provided.

  4. 2.8 inch color screen, text with graphics, convenient operation and fluid analysis.☆

  5. Can store up to 10,000 pieces of data, and can be exported through the included USB flash drive.☆

  6. Sensor power consumption is low: power consumption < 0.8W during flow measurement.☆

  7. Chinese and English operation interface, support one-key switch.☆

  8. Built-in rechargeable lithium battery, working time over 8 hours.

  9. Built-in pressure water level sensor, temperature sensor.

IV. Technical Indicators

ParameterScopePrecisionResolution
Flow rate range0.020m/s~6.00m/s☆±1.0%±1mm/s1mm/s
Water temperature measurement-10℃~60℃±0.1 (℃)0.1 (℃)
Depth of water measurement range0.03 meters to 10 meters0.3%±0.5cm1mm
Instantaneous flow range0.001~9999m3/h☆±3%0.001m3/s
Cumulative flow0.001~9999m3☆±3%0.001m3

5. Performance indicators

ParameterScopeNote
Working voltage10.0V~12.6V DC
Battery capacity1800mAh☆
整機 power consumptionLess than 2.4w12V power supply
Working hoursGreater than 8 hours
Cable length20m
Working water depthless than 10m
Data update cycle1 time/second☆

Six, Use Requirements

1. The gas guiding cable contains a gas guide pipe, which cannot be overly bent to prevent it from breaking; never use the gas guiding cable as a rope for the Doppler flow meter, dragging the Doppler flow meter with the gas guiding cable;

2. The circular ultrasonic transducer in front of the probe cannot be impacted or scratched;

3. The instrument probe should avoid being exposed to the sun for a long time to prevent too high a temperature from causing a fault;

4. The acoustic doppler current meter should be regularly cleaned of silt on the ultrasonic transducer and pressure sensor in areas of high suspended sediment concentration to prevent the silt from blocking the pressure sensor.




Product address:http://www.shenzhensmofreer.com/en/liusuyi/1647.html
Hello, my friend!
What kind of support do you need? Our products is sure to satisfy you.
*Name
*Email
WeChat
Phone
Country
*Message
主站蜘蛛池模板: 中超| 三河市| 博客| 九江县| 临夏县| 洞头县| 万全县| 民勤县| 依安县| 乌兰察布市| 舞阳县| 平武县| 同德县| 应城市| 常州市| 仪陇县| 尼勒克县| 元阳县| 台南市| 历史| 北安市| 广东省| 桃源县| 凉城县| 颍上县| 呈贡县| 顺昌县| 金秀| 上栗县| 道真| 高雄县| 尉氏县| 黎川县| 阳泉市| 宁阳县| 淮安市| 兴隆县| 固镇县| 息烽县| 陈巴尔虎旗| 墨脱县|